It would be interesting to know the efficiency of the Expert amp at various voltage/power levels.

John KK9A



Roger D Johnson n1rj wrote:

I just did a quick check:

At 1500 watts eff is 56% and pwr diss is 1179 watts
    1000              44                  1273
     500              30                  1120

My Expert 1.3K-FA had 3 voltage levels:

48 volts for full power (1300 watts)
38           800 watts
32           450

I no longer have the amp so I can't check the eff at those
voltages and power levels.