The bias would do nothing for low power. Low power can be implemented in two ways, with different taps at final transformer (KX3), and with different supply voltage (Expert amps). The first one is hard at a KW level. The second one requires power supply with different voltages. If the power supply can deliver only one voltage, not much can be done.
Ignacy, NO9E -- Sent from: http://elecraft.365791.n2.nabble.com/ ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [email protected]