It's probably worth emphasizing that the KPA500 is only vulnerable to a 
spurious "D" command when it is in "powered but off" state.   Perhaps the 
problem can be avoided by changing the sequence of remote station power up so 
KPA500 is only powered when the server is stable.  It may also help to limit 
the amount of time the KPA500 is in "powered but off" state.

Seeing what the server is sending may be useful.  I found my Rigol DS1054Z 
scope to be very helpful during my controller development.  When investigating 
my spurious loader issue I was able to capture the offending RS-232 data and 
see how it could be decoded as "D" even though "D" had not been sent by my code 
and was not present in the TTL signal.

73,
Andy, k3wyc