On 2/26/2020 5:14 AM, [email protected] wrote:
Aside from installing ferrite on all cables (not sure why this isn't
integrated somehow if it's that large of an issue) would having the shack
walls lined with a grounded screen help reduce/eliminate radio noise?
Is the cost/effort worth it?
Of course not. RFI is received by ANTENNAS, not wiring in the station.
The things that ARE important are 1) proper bonding of all equipment in
the station; 2) bonding of the station to all grounds in the home; 3)
elimination of all noise sources in your home, and 4) application of
effective ferrite chokes to those sources you can't elimnate.
http://k9yc.com/KillingReceiveNoise.pdf
http://k9yc.com/GroundingAndAudio.pdf
73, Jim K9YC