When considering the upper temperature limit of a KPA500 I think it is 
important to know if, for the planned operating condition, the temperature 
limits at a value that the owner is willing to accept.  In other words,  does 
the fan produce sufficient airflow for the temperature to reach its maximum 
before thermal protection kicks in.  If it does, what is that limiting 
temperature and is it acceptable?

I have not tested any higher than 70 deg C and don't have any plans to do so.   
I don't want to operate there because the fan noise is intolerable.  If I felt 
the need to operate in that region I think I would duct a much larger 
fan/blower to the rear chassis fan opening.

Data from one of my test runs shows the front left heat sink fin was only at 47 
deg C when the finals peaked at 70 deg C.  The heat sink temperature continued 
to rise after TX stopped and peaked at 48 deg C.   This suggests to me that the 
thermal path between the finals and the heat sink could be improved but I have 
no expertise in this field.

73,
Andy, k3wyc