Bob
I'm steering slightly off course and I feel I must come in: I presume that 
during the manufacturing process, the amplifier goes through a production 
process to set up the indicators using a lab quality load and modern, lab 
quality power meter, regularly calibrated.  I have a Bird with various slugs 
and dummy load but I would not assume it was even close to the accuracy that 
Elecraft achieve even if I had just had it calibrated the day before.  From 
memory the Bird is *only* 5% accurate on the day of calibration, whereas a 
modern lab quality digital power meter must surely be far better, perhaps in 
the 1% region.  So, I'm questioning the need to change the factory settings.  
While on this topic, I'm curious to know how long the factory settings last and 
to what accuracy. 

Apologies for the drift. 

73 David G3UNA


> On 16 May 2020 at 18:45 Bob McGraw K4TAX <[email protected]> wrote:
> 
> 
> I wouldn’t run the KPA500 at half power. And 25 watts of drive is certainly 
> more than mine requires to attain rated power, except on 6M where it requires 
> 25 watts.  
> 
> As to power output indicators, I used my Bird43 and a 500 watt element with a 
> known good 50 ohm load.  I then calibrated the indications per the manual for 
> my KPA500.   That’s when I did the ALC calibration and setup for each band. 
> 
> Sure works nice when everything is correct and correctly calibrated. 
> 
> Bob, K4TAX
> 
> 
> Sent from my iPhone
> 
> > On May 16, 2020, at 12:25 PM, TL_Netvision <[email protected]> wrote:
> > 
> > 
> > 
> > Hello Elecrafters
> > 
> > 
> > 
> > Thanks for your time on this, & I hope to find you all in good health 
> > 
> > 
> > 
> > My setup is K3+KPA500+KAT500.
> > 
> > 
> > 
> > 
> > 
> > Sometime ago due to probably high SWR  (water in the Pl259 leading to
> > KAT-500) the KPA-500 stopped after a loud noise (can't tell whether KPA or
> > KAT) was heard. 
> > 
> > When I reset it & checked all bands into a dummy load (no tuner), It
> > delivered half the regular output power on all bands. (25w in for appx. 150w
> > out). 
> > 
> > 
> > 
> > I don't know if this means 1 side of the PA is gone,  or is there  some 3db
> > pad connected permanently.
> > 
> > 
> > 
> > Any ideas for test procedures? 
> > 
> > Also how safe (forbidden?) is it to operate the amp in this "half-power"
> > condition?
> > 
> > 
> > 
> > 
> > 
> > Thanks in advance, 
> > 
> > 
> > 
> > Isaac, 4Z1TL
> > 
> > KPA SN 01090
> > 
> > 
> > 
> > -- 
> > This email has been checked for viruses by Avast antivirus software.
> > https://www.avast.com/antivirus
> > ______________________________________________________________
> > Elecraft mailing list
> > Home: http://mailman.qth.net/mailman/listinfo/elecraft
> > Help: http://mailman.qth.net/mmfaq.htm
> > Post: mailto:[email protected]
> > 
> > This list hosted by: http://www.qsl.net
> > Please help support this email list: http://www.qsl.net/donate.html
> > Message delivered to [email protected] 
> > 
> 
> 
> ______________________________________________________________
> Elecraft mailing list
> Home: http://mailman.qth.net/mailman/listinfo/elecraft
> Help: http://mailman.qth.net/mmfaq.htm
> Post: mailto:[email protected]
> 
> This list hosted by: http://www.qsl.net
> Please help support this email list: http://www.qsl.net/donate.html
> Message delivered to [email protected]
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected] 

Reply via email to