Read the following: 1) K144XV manual pp20 2) K144XV Reference Oscillator Phase Lock Option Manual. Pp 11
Once the K3S 49MHz oscillator is calibrated, leave alone. The LOs (plural,,,116MHz and 118MHz) are locked to the 10MHz reference (which, depending where you are in the 2M band). If there is no 10MHz reference applied, keeping the desired accuracy may be impossible over a range of temperature. You should be able to attain +- 10Hx accuracy according to the K144XV manuals. If the 800Hz error cannot be corrected by the procedure outlined, I suggest contact Elecraft support. Ben W4SC Sent from Mail for Windows 10 ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [email protected]