Hello everyone,

    During the alignment of the Top Band option of my K2 I did a stupid thing 
and connected the dummy load to the wrong antenna connector. I used the tune 
button and tried to align the filters to set the TX power using the power level 
set to 2 watts. I got a high current warning on the display and then no power 
out. So it looks like I have damaged the PA by transmitting into no load. The 
net result is that I have no TX on all bands. There was no smoke, no excessive 
heat and no visual damage to components. The K2 ATU option displays 0.1:1 when 
I hit the tune button (incidently I thought the K2 should display power out 
when the tune button is pressed) and the Motorola test set I use indicates 0 
power out. RX seems fine.

    I can only work on the rig at the weekends and there is no friendly 
component shop handy where I live. Clearly I will need to replace something. So 
I was thinking of ordering the components which might have failed by mail order 
and what I dont use will go into my spares store. Any ideas what I should order 
and or where the fault might lie....

    Thanks in advance,

Steve