Don and gang, I replaced Q3, U1 and the ADEX mixer. Results? Transmit works FB as before and the RX still has no sensitivity. No change at all. I ran through the setup related to the RX section and one thing stands out.
Part VIII: RX Input Alignment Trimmer cap C1 has no effect on the AC voltage at the phone output connector. This is the same result I had before replacing the 3 parts. I think I may be down to signal tracing starting at the N connector. But without a list of test points and voltages, this may be a nonproductive PITA. The next step is to sell this unit for parts or buy a working used XV222 so I can backward engineer a solution. 73, Mark K2QO -- Sent from: http://elecraft.365791.n2.nabble.com/ ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [email protected]