I have a fairly new Kidde wired system (battery / AC) with a total of 10 sensors on 3 levels.
No RF issues with KPA/KAT500 at full power on any band 160-6m, any mode. 73 Lyn, W0LEN -----Original Message----- From: [email protected] [mailto:[email protected]] On Behalf Of VA3LX Sent: Sunday, November 08, 2020 1:22 PM To: [email protected] Subject: [Elecraft] OT: Kidde smoke detectors; Any follow up on RFI frm wireless models? Hello, I read the thread from several weeks ago discussing the Kidde wireless interconnected smoke detectors and the concern that they would be triggered by RF from ham radio. Has anyone who is running any power tried them? A local ham running 100 watts hasn't had problems. I have a Kidde wired interconnection smoke detector system that I trigger with > 250 watts. Numerous attempts with ferrite chokes and bypass capacitors haven't resolved it. TNX de Paul VA3LX -- Sent from: http://elecraft.365791.n2.nabble.com/ ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [email protected] ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [email protected]