On 12/25/2020 7:12 PM, Andy Durbin wrote:
KPA500 has no "BYPASS" mode. It is either Off, On in STBY, or On in OPER.
Picky, picky, picky. :) When all of the power amps I'm aware of are in a mode usually called "Standby," meaning that they are powered up and ready to transmit, but are Bypassed. they are Bypassed. They are also Bypassed when turned off. And when tube amps are prevented from transmitting when their filaments are warming up, they are Bypassed.
73, Jim K9YC ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [email protected]

