On Fri, Feb 12, 2021 at 11:46 AM David Reed <[email protected]> wrote:
>
> I need some help figuring this out; I can do the power down from the Elecraft 
> Utility (using command "PS0;")
>
> In trying to get it to run from Commander, I have done the following (but no 
> results); other than this, Commander is working fine.
>
> User -defined Command Sequence:
>     Note:             Power Off
>     Command:    PS0;

Try the following:

'PS0;

ASCII commands must be prefixed with a single-quote - see
https://www.dxlabsuite.com/commander/Help/CommandSequences.htm

73,

    ~iain / N6ML
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected] 

Reply via email to