My ESD concerns started when I had completed my K2.  There were occasions upon 
turning on my K2 that my finger approaching the VFO knob would cause my K2 to 
lock up.  (BTW, the rig was well grounded.)  As it turns out, it was my finger 
approaching the mike connector that caused the problem.  I suspended two small 
springs between the two mike connector mounting screws to ground the floating 
mike connector and eliminate the ESD.  ESD is very real for sure!   Thank 
goodness, grounding the mike connector cured this problem.  Roy Morris  W4WFB
No virus found in this outgoing message.
Checked by AVG Free Edition.
Version: 7.1.394 / Virus Database: 268.10.4/396 - Release Date: 7/24/2006
_______________________________________________
Elecraft mailing list
Post to: [email protected]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
 http://mailman.qth.net/mailman/listinfo/elecraft    

Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com

Reply via email to