I just tried it with a brand-spanking new 50ohm BNC terminator. This eliminated 
the cable and adapters I needed for my 50 watt dummy load. 

Same result.

> On Jan 6, 2023, at 8:42 AM, Chuck Shefflette <[email protected]> 
> wrote:
> 
> Bill,
> 
> I've had similar things happen. Try a different dummy load and/or cable and 
> make sure all the connectors are tight. A slight mismatch at that power level 
> will really make a difference.
> 
> 73,
> Chuck, AA3CS
> 
> On Fri, Jan 6, 2023, 08:38 Bill Coleman via Elecraft 
> <[email protected]> wrote:
> I have two K3s, and both are failing the milliwatt calibration. One fails on 
> 160m, the other on 6m, both with similar error messages.
> 
> This is an example of the failure:
> 
> Calibrating at 1.900 MHz
> IsSamplingComplete: Unexpected response ‘DB 2.08 MW;’ to ‘DB;’.
> Calibration power settled at ‘2.08 MW;’
> 1 milliwatt calibration failed.
> 
> 
> Any ideas?
> ______________________________________________________________
> Elecraft mailing list
> Home: http://mailman.qth.net/mailman/listinfo/elecraft
> Help: http://mailman.qth.net/mmfaq.htm
> Post: mailto:[email protected]
> 
> This list hosted by: http://www.qsl.net
> Please help support this email list: http://www.qsl.net/donate.html
> Message delivered to [email protected]

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected] 

Reply via email to