There can be another source for "clicking" in the KPA500. See: https://groups.io/g/Elecraft-K3/message/38986

On 11/13/2024 7:03 PM, Andy Durbin wrote:
I found the thermal clicking to be annoying and I tried to understand what 
caused it.  I instrumented my KPA500 with thermistors on the heat sink and on 
the Z bracket.  I recorded these temperatures together with the standard finals 
temperature over many hours of KPA500 use.

I could see that the thermal flow between the heat sink and the Z bracket 
changed direction and I speculated that this changing thermal gradient was 
causing differential expansion and contraction.  I planned to put thin mylar 
isolation strips between the Z bracket and heat sink and between the heat sink 
and the side panel.  I thought these would allow the surfaces to slip without 
making any noise.

However, my natural procrastination paid off and my KPA500 stopped clicking 
before I got round to implementing any fixes.

Andy, k3wyc