Hi Elecraft

I'm trying to get the Auto ATU going again after  static zapp (at least that's 
what I suspect happened).  I've replaced the ATU PIC and once again it checks 
out with the tests on p13 of the manual.  I've also successfully set C55 to 
give an indication of 000.

When I go on to attempt the power calibration, I run into problems.  I set the 
power control for 5 watts but when I hit TUNE I see 10 to 12 watts on the power 
meter (external with 50 ohm dummy load) for one or two seconds, then the power 
is cut off.

All suggestions gratefully received!

Yours

Andrew, G4HVC
_______________________________________________
Elecraft mailing list
Post to: [email protected]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
 http://mailman.qth.net/mailman/listinfo/elecraft    

Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com

Reply via email to