Hi Bob,
Thanks for the great feedback!
Actually the W1 already has the capability of displaying a peak hold led
as you described. It is enabled via the W1 serial command set and can be
stored permanently in eeprom so that it is on by default each time you
power up your W1. (Hint: Use the "P" command followed by the "W"
command.) Take a look at the W1 manual for a full description of the W1
serial command set and how to communicate with the W1 using a terminal
program like Hyperterminal.
We're also adding this command to the next version of the W1 Windows
control program to make it easier to set it up on the W1. Watch our web
site in the next week for the latest version :-)
73, Eric
[EMAIL PROTECTED] wrote:
Hi everybody.
My little W-1 has been getting a bit of a workout around here. I think
this the best piece of Elecraft test equipment yet!
An option that I'd really like to see would be a peak hold indication for
checking voice modulated output of my K2. Kind of a fast attack/ slow
decay. For those of us without a 'scope this would seem to be just the
ticket.
Just a little bit of program enhancement should do it.
73s, Bob K7HBG
_______________________________________________
Elecraft mailing list
Post to: [email protected]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com