Karsten Eppert(DK4AS) wrote:
No doubt: ist works, but I have a question in mind. As far as I understand, the latching relays are switched back and forth by short pulses from the I/O-controller. But: how does the controller know the initial stage of the relay in order to switch to the desired position? How does the controller know the position of the relay after power failure with complete controller-reset?

It looks to me as if the relays are set or reset by reversing the
polarity.  One side of all the relays are connected together and the
other sides go to IO controller ports.  By making all the ports high
except for one, the result is to apply a negative voltage to the one
connected to the low port, resetting it.  To set the same relay, all the
other ports are made low and its port is high.  In either case, the
current flowing through the other relays is insufficient to affect them.
 Ingenious, isn't it?
--
73,
Vic, K2VCO
Fresno CA
http://www.qsl.net/k2vco

_______________________________________________
Elecraft mailing list
Post to: Elecraft@mailman.qth.net
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com

Reply via email to