Just to close this thread in case anyone was wondering about it, I installed the KPA100UPKT today and it solved the HI CUR on 30m problem. The K2 now draws less than 1.7 A on 30m with 100 W tx into dummy load compared to 4.1 A before. What a nice change. My thanks to Don and the Elecraft Parts crew!

K1 #2298 was just finished this morning as well. What will I do with all this extra time now? Not sure I still remember how to operate the rigs. :-)

73,
Mike  ab3ap

Don Wilhelm wrote:
...If the turns on the
KPA00 low pass filter toriods are correct and all the C3x capacitors are
correct, you may want to install the KPA100UPKT and see if that brings
things under control...

73,
Don W3FPR

-----Original Message-----

I just noticed I'm getting a Hi Cur message only on 30m.
...
Mike  ab3ap
_______________________________________________
Elecraft mailing list
Post to: [email protected]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com

Reply via email to