Joe,

You likely fried the MMIC chip.  Get another MMIC and install it, the Ngen
will be good as new.

I have done that soeveral times, so don't feel like the 'lone ranger'.  Slap
your wrists a couple times and vow not to do that again! <G>  But I keep a
couple MMICs on hand just in case.

73,
Don W3FPR

> -----Original Message-----
>
> I suppose when I had the Ngen connected to the QRP K2
> and accidentally pushed the MSG button causing some CW
> to be sent means I fried the Ngen circuit.  no?
> de Joe, aa4nn
>
--