Nick,

Look at the schematic and you will see that there is a connection between leads B and C are connected. The proper time to check for shorted wires is before soldering onto the board - everything will appear shorted for DC (but not RF) after soldering on the board.

73,
Don W3FPR

Nick T - NT1A wrote:
Hello,

I am just about to finish up K2 kit # 6163 and I have a question about toroid 
T3.

When I do a continuity check between legs a,b,c, and d my meter is showing that 
all legs are connected electrically. Is this correct for T3?

Under close inspection with a magnifying glass I do not see any shorts between the red 
and green wires so I assume the legs are connected "further up the road" 
between the traces on the pc board.

Please let me know if I am on the right track before I button her up! Thanks!
_______________________________________________
Elecraft mailing list
Post to: [email protected]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com

Reply via email to