Nick,
Look at the schematic and you will see that there is a connection
between leads B and C are connected. The proper time to check for
shorted wires is before soldering onto the board - everything will
appear shorted for DC (but not RF) after soldering on the board.
73,
Don W3FPR
Nick T - NT1A wrote:
Hello,
I am just about to finish up K2 kit # 6163 and I have a question about toroid
T3.
When I do a continuity check between legs a,b,c, and d my meter is showing that
all legs are connected electrically. Is this correct for T3?
Under close inspection with a magnifying glass I do not see any shorts between the red
and green wires so I assume the legs are connected "further up the road"
between the traces on the pc board.
Please let me know if I am on the right track before I button her up! Thanks!
_______________________________________________
Elecraft mailing list
Post to: [email protected]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com