Hi Friends
I have got a problem with my K2/100 and need your help.
I built K2, KPA100, KSB2 and KAT 100 which worked OK for years from the first day until now. Recently I upgraded the KPA100 with KPA100UPKT, it passed all tests (I did not realign it), and it worked perfectly for two weeks. One day I worked in the morning without any trouble, but when in the afternoon I fired it up again, the KAT100 was unable to tune: relays clicked, diodes did not light, tune was not obtained.
I disconnected KAT100 and observed that K2/100 was not working right.
Connected to a dummy load, power and swr readings in the LCD display are:
   Setting  9 w         Read  9.8 w   swr  1.2.1
   Setting 30w         Read  27 w    swr  1.8.1
   Setting 90w         Read   64 w   swr   2.4-1     first appears HiCurr
The bare K2 (disconnected from KPA100) shows no problem. Connected to the same dummy load and to an OHR qrp wattmeter, power indications agree in both LCD and wattmeter and swr is negligible. So I repeated all tests made when I built the KPA100, all were all right but D13 cathode voltage was 0 v. instead of 90 to 150 v. (K2 and KPA100 connected only with the ribbon, power supply only to the K2). Resistance between D13 cathode and ground is >10k. Then I connected again K2 and K100, power supply to the KPA100, and checked voltages of diodes D11 to D14. I remarked notable divergencies:
Diode                     D11          D12         D13          D14
anode Tx 9 w --- --- --- 13.3 v anode Tx 90w --- ----- -2.2 v -2.2 v
cathode  Rx  9 w    13.4 v       126.2 v    13.4 v       126 v
cathode Rx 90 w     3.4 v           -----         13.4 v        ----
cathode Tx  9 w      13.4 v        123.4 v    13.4 v      122.8 v
cathode Tx 90 w          ---          126.9 v      -1.4 v     127.6 v
Where not reported, read and standard values did not differ substantially.
I suspected 90-150 v bias voltage, so I checked the involved diodes.:
   anode        cathode
D1 23 108 D2 23.7 70.2
D3    ----            -----
D4    ----            ----
D5    16.2        31.8
D6    -----          16.5
D7    -1.5        -1.4
D8    -1.7        -----

Where not mentioned, read and standard values did not differ substantially.
Should I conclude that the problem is here? And if yes, how to find the defective component? Or should I look anywhere else?
I did not find anything similar in the reflector.
Your help will be greatly appreciated!!
I do'nt know whether the trouble was caused by a failure of the KAT100.
Sorry for the long explanations, but I hope they will help.
My electronics knowledge is rather poor.
73
Raimon   EA3EZO
[EMAIL PROTECTED]

_______________________________________________
Elecraft mailing list
Post to: [email protected]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com

Reply via email to