Stefan I too have a K2 and Acom 1000 and have experienced the same problem. As I usually use the K2 for CW at just 100W I have done nothing to tackle the problem - I just use the Acom with my TS2000 on those rare occasions I want to run SSB.
This is a known problem - take a look at this (and the subsequent messages in the thread): http://marc.info/?l=elecraft&m=113376989224579 Hope that helps.... 73 David G3XLW ON4FG <[EMAIL PROTECTED]> wrote : > Hi, > > I just got an ACOM-1000 that i am using with my K2. > When I am drivng it with 13...14W for approximately 300W output, I noticed > that I got a power output reading in excess of 1kW during the start of my > SSB transmission, just for a second or less. CW seems to be ok. > Does anyone else noticed this? What can be done about it? > I heard that some FT1000 had a transient, putting 200W into the amplifier at > > the start of the transmission, and the PA did not survive this. > I do not want this to happen with my PA. > > 73 > Stefaan ON4FG / OP4T / TZ4T > > _______________________________________________ > Elecraft mailing list > Post to: [email protected] > You must be a subscriber to post to the list. > Subscriber Info (Addr. Change, sub, unsub etc.): > http://mailman.qth.net/mailman/listinfo/elecraft > > Help: http://mailman.qth.net/subscribers.htm > Elecraft web page: http://www.elecraft.com _______________________________________________ Elecraft mailing list Post to: [email protected] You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com