Don, Thanks for your quick reply. Following values are Vrms made with Elecraft RF Probe and DDM. (7 MHz value/14 MHz value) Q1 gate : 0.17 / 0.16 Q1 Source : 0.11 / 0.18 Q4 base : 0.10 / 0.18 Q5 base : 0.9 / 1.1 Q5 collector : 4.7 / 6.0 Q6 base : 1.3 / 1.2 Q6 collector : 8.9 / 10.7
I suppose these values are quite consistent. Q5 collector values and Q6 base values seem to have the same relation betwenn them as the impedances (1:3). Am I right ? Thanks for your help. 73 Luc/F6HJO/HB9ABB _______________________________________________ Elecraft mailing list Post to: [email protected] You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com