Fred,

There is no 'reboot' possible with the KAT100.

Either you have a really bad load on the KAT100 (like a short or open circuit), or the 1N5711 diodes have been zapped by a static surge of some type (like lightning). Replacing the diodes usually cures that behavior.

73,
Don W3FPR

Fred Jensen wrote:

DIFFERENT SUBJECT: My KAT100 seems to have lost it's tuning brains. Is there something I can do to reboot it? Feeding a dummy load, it rattles relays like mad, finally gives up at 9:1 SWR.

73,