I am building a KPA100 and it is configured as -12V supply attached -12 v internal line connected to K2 at P3 -PA turned on in menu
In attempting the power calibration the K2 shows i watt when set for 5 watts. Adj R26 has no effect. Checking back with the RF probe, I find that K2 shows 11-12 vRF and with the RF cable connected to KPA100 it shows 11-12 VRF at the input of K1. However at TP2 there is no RF. I took the board off the heat sink and I find that the RF goes to the n.o. terminal rather than to the nc terminal. So the signal is lost in Ki Has anyone had this experience with the KPA100 or can anyone give me any ideas how to correct this? Thanks, Earl _______________________________________________ Elecraft mailing list Post to: Elecraft@mailman.qth.net You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com