You've got it--
1. Turn the K2 off.
2. Hold down the 4, 5, and 6 keys
3. Turn the K2 back on.
The EEPROM will be re-written with the factory defaults for all
settings, which will require that you re-run all of the calibration
functions again.
BTW, it's on Page 106 of the manual.
73,
Dave K7DAA
http://www.k7daa.com
On Mar 25, 2008, at 8:37 PM, DW Holtman wrote:
Hello,
A few weeks ago, someone posted a procedure for reseting a K2. It
was a sequence something like holding the 4,5 and 6 buttons while
powering up.
What is the sequence? Does it reset everything, filters, sidetone
etc to it's factory settings? I could not find it in the manual or
in the archives.
Thank you in advance for your help.
Best,
DW Holtman
WB7SSN
_______________________________________________
Elecraft mailing list
Post to: [email protected]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com
_______________________________________________
Elecraft mailing list
Post to: [email protected]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com