In a recent message, Ken Wagner <[EMAIL PROTECTED]> writes
I measured C222 *in place* with my aade cap checker and it measured ~1 uF(actually 0.965 uF)... not the 0.1 in the schematic. I'm guessing that the schematic available for download is not current with production. Someone else here mentioned that C222 was 1 uF, but I don't remember who it was.

Thanks Ken, and Dave G4AON, it looks as though a batch of RF boards were fitted with the wrong value of C222 SMD. Perhaps we should all measure C222 before changing the capacitor.

73
--
David G4DMP
Leeds, England, UK