Good day, Recently I noticed a brief flash of ERR PL1 when changing from 17M to 15M. It happened maybe a dozen times. Not noticed before, not noticed since. I didn't record the exact frequency this was happening on.
PLL 1 voltage on 15M: 21.000 5.2 21.050 5.5 21.100 5.8 21.150 6.0 21.200 6.3 21.250 6.6 21.284.399 6.9 21.284.400 2.4 21.300 2.4 21.350 2.5 21.400 2.7 21.450 2.8 Looks like there is a VFO range switch near the middle of the band. I assume this is normal. I just might have been right on the transition point, though I believe I altered the tuning to see if the RX was working OK between tests. Regards, Mike VP8NO _______________________________________________ Elecraft mailing list Post to: [email protected] You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com