The numbers reported below are close to what I would expect if the 2.7 kHz and 500 Hz column labels were accidentally switched. Typo maybe?
Doug N0HH ========================================================================= Yes something isn“t right. This was his measurements: CLOSE-IN INTERMODULATION ON 7MHz band,500Hz bandwidth, CW preamp off 2.7 kHz roofing 1.8 kHz roofing 500 Hz roofing 2kHz +19dBm 101dB +12.5dBm 96dB +2.5dBm 88dB 3kHz +19dBm 101dB +12.5dBm 96dB +2.5dBm 88dB 5kHz +22dBm 103dB +12.5dBm 96dB +8.5dBm 92dB 7kHz +22dBm 103dB +12.5dBm 96dB +13dBm 95dB 10kHz +22dBm 103dB +12.5dBm 96dB +17.5dBm 98dB 15kHz +22dBm 103dB +12.5dBm 96dB +22dBm 101dB 20kHz +22dBm 103dB +12.5dBm 96dB +25dBm 103dB 30kHz +22dBm 103dB +12.5dBm 96dB +26.5dBm 104dB 40kHz +22dBm 103dB +12.5dBm 96dB +27dBm 104dB 50kHz +22dBm 103dB +12.5dBm 96dB +27dBm 104dB _______________________________________________ Elecraft mailing list Post to: [email protected] You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com