Are you in PA NOR or in PAIO NOR?

You need to be in PA NOR to enable high power.

Bob NW8L

On Fri, Jun 20, 2008 at 9:01 PM, Bill Maddock <[EMAIL PROTECTED]> wrote:
> I just installed the KPA3 - the fans work in the test mode - I let the
> config in NOR instead of not installed. I am still only seeing 12 watts
> out - running the 1.96 firmware that came with it. I set the PA temp
> according to the sheet - I can not get xmit LP to HP for so reason -
> any ideas - maybe I'm just tired? The fuse leads are hooked up.
>
> Question #2 I know that you have to configure the roofing filter for
> each mode - Do they need to be configured on each mode on every band
> or just one of the bands to cover for all bands?
>
> Anyone got any ideas?
>
> Thanks and 73,
>
> Bill N4ZI
>
>
>
> _______________________________________________
> Elecraft mailing list
> Post to: [email protected]
> You must be a subscriber to post to the list.
> Subscriber Info (Addr. Change, sub, unsub etc.):
>  http://mailman.qth.net/mailman/listinfo/elecraft
>
> Help: http://mailman.qth.net/subscribers.htm
> Elecraft web page: http://www.elecraft.com
>
_______________________________________________
Elecraft mailing list
Post to: [email protected]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
 http://mailman.qth.net/mailman/listinfo/elecraft    

Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com

Reply via email to