In the manual errata, the following mentions setting alternative filter "norm" settings. I think this has been mentioned previously, but mine doesn't seem to work as the manual errata suggests it should. The "-SAV-" appears but only for a split second, not allowing time to pick an alternate... I am using firmware 2.13, but haven't tried using the ALT filter settings previously.

From the manual errata:

In addition to the K3's standard "NORM" values, you can save two of your own often-used filter setups in each mode, and recall them using the NORM function. These are referred to as ALT1 and ALT2. To save a filter setup, hold NORM until you see "<- SAV ->" (3 seconds), then rotate the knob left or right to save it as ALT1 or ALT2. (The arrows to the left and right of "SAV" are a reminder that you can rotate the knob left or right go get to the "ALTernate" filter memories.) To recall, hold NORM until you see "<- NOR ->" (about 1/2 second),
then rotate the knob left or right to recall ALT1 or ALT2.

73 Dave
_______________________________________________
Elecraft mailing list
Post to: [email protected]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com