Don,
The XG1 output isn't enough signal for the scope (and its output, which
is connected to my freq counter).
No adjustment cap either.
http://www.aade.com/newfreq/new%20freq.htm does have merit. If there's a
cap in there to
tweak at some future time, then it should do the trick.
Thanks,
Alan--
Alan D. Wilcox, W3DVX
570-321-1516
http://WilcoxEngineering.com
Williamsport, PA 17701
Don Wilhelm wrote:
Alan,
Why not just build an XG1 and put a 10 MHz crystal in it - it will
only do -73 dBm output as a stock item, but I am certain you could run
it through an amplifier.
Of course, there is always the AADE frequency standard that claim 1ppm
long term accuracy.
73,
Don W3FPR
Alan D. Wilcox wrote:
Hello,
Want 10-MHz crystal oscillator that puts out a volt or so for
frequency counter calibration check.
Must have cap to set freq zeroed onto WWV for a few minutes
operation; no long-term stability required.
Something like the XG1 ... battery, BNC, not fancy.
Thought this would be simple search ... a kit-builder's project.
Guess nobody's making such a kit.
Anybody have or know where to get?
Thanks,
Alan
_______________________________________________
Elecraft mailing list
Post to: [email protected]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com