Chuck, I had a quite similar problem. My K3 was qrp waiting for the KPA3. When pushing tune I had full power (12W). Talking SSB I had full 12W but when I touched the power knob, even reducing 0.1W caused the power to drop to 8W peak. I had to retune to resume full power. I checked the LPA twice but at last I noted that it wasn't fully inserted. I pushed it firmly and now is working fine. Ciao
Max IW0GXY Chuck - AE4CW wrote: > > I am seeing an approx. 20% reduction of peak SSB power after pressing ATU > TUNE. This occurs at both 50 and 100 watts into a high-quality dummy load > as indicated on the K3 RF bar display and my external LP-100A wattmeter. > Bypassing the ATU does not restore the peak power, so I don't think it's > caused by the ATU. Pressing TUNE does restore full peak power until I > press ATU TUNE again which causes the peak power to drop by approx. 20%. > I see this behavior in firmwares 2.02/1.77 and the beta 2.15/1.84. > > I presume this is a firmware issue and will report to Elecraft but wanted > to see if others are experiencing the same problem. > > Chuck, AE4CW > -- View this message in context: http://n2.nabble.com/K3-Firmware-Bug--Power-Reduction-After-ATU-TUNE-tp534144p534425.html Sent from the Elecraft mailing list archive at Nabble.com. _______________________________________________ Elecraft mailing list Post to: [email protected] You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com