Pierre,

That strongly suggests that your KPA100 has a parasitic.
If your KPA100 is of recent vintage (less than 2 years old), it should 
be quite stable.
But, if you have added the KPA100UPKT, I must ask if your upgrade kit 
included a new C31 capacitor of 0.22 uF value.  Many KPA100UPKT kits did 
not include this capacitor until recently.  If this situation fits your 
case, send an email to [email protected] asking for a new capacitor for 
C31.

If your KPA100 is of the older T/R switch design - red cores for L15 and 
L16, then I would suggest that adding the KPA100UPKT would solve your 
problem.  The current KPA100UPKT includes the new capacitor for C31.

73,
Don W3FPR

Pierre wrote:
> Well I spoke about the SWR meter on my MFJ-949E. If I send CW, when I 
> release the key, the reflected power needle goes up wildly.. sign of a 
> high SWR... even at 11 watts.
>  
> But that same needle stay at 0 W for a 10 Watts transmission...
>
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to