Thanks in advance for any advice...

Symptom:
Without filter board installed, unit powers up and passes LED tests. Absolutely 
nothing appears at any time on the LCD display.  I thought I might be having a 
display problem until for giggles and grins, I popped in the filter board and 
powered up.  With filter board in, LEDs behave as expected, relays can be 
heards twiddling, and then the E42 error code is displayed for a short time and 
then the display goes blank again.

In either case, with the display blank, subsequently pressing any of the 
buttons produces nothing.

Other things I've done... I've looked at every pin of the display with a scope 
to verify no shorted pins.  Likewise, I've looked at every pin of the PIC on 
the FP board with a scope to verify no unexpected shorts to gnd or Vdd.  Can 
see activity on the SDA and SCL lines as well.  Checked U4 for proper voltage 
out.  I've physically inspected every connection to check for improper 
soldering.  (I'm a very experienced kit builder and can honestly say I've not 
had a problem with improper soldering.  I've missed the occasional pin though 
;-)  Physically inspected RF board as well.  Voltages good.  Solder joints all 
seem good and present!

The PIC on the FP board is definitely running, and because the E42 error code 
displays, albeit temporarily, I know the display is good.

Why no E27 code at all?  Why doesn't E42 code stay, so that a tap of a button 
gets me to the next state?  Again, thanks for your consideration,

Kelly NN8E


______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to