Is this something that just happened, or has it possibly always been there unnoticed? In any case, a change to the BFO frequency of one or all filters is in order.
The condition should be cured by doing a filter alignment. I highly recommend using Spectrogram to do that task. See my website www.w3fpr.com - article on K2 Dial Calibration, the filter alignment info is in part 3 of that article. 73, Don W3FPR KG4UFV wrote: > I have encountered a problem with my K2. When I change from Filter 1 to > Filter2 in CW mode the cw signal shifts 600hz down in frequency. Has anyone > experienced this before? > > ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html