turned off/uplugged the k3 last night, all was working well Turned on the K3 this morning, had both error messages "ERR AT3" and "ERR PL1"
"ERR PLI" was the most immediate, in this state there was no main vfo tuning, so I consulted the manual did a "config: vco md" recalibration of vco1. It failed with error message err05 on the display just on a hunch, I wondered if anything memory wise had got corrupted so I reloaded ALL the 3.14/dsp2.16 software After finishing, i had NO "ERR AT3" error, but i did still have the "ERR PL1" error. I wasnt too surprised at the latter error as it had just failed calibration redid the "config: vco md" recalibration of vco1, it passed this time On power off/on no error messages All is now well again in the land of the K3 Incident cost me 30 minutes of valuable painting time before the texas heat calls a timeout! Dave ww2r ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html