That may be the case.  But the instructions are very specific about  
"open circuit as if the test meter leads were not connected to  
anything".  Even 14 megohms doesn't meet that definition.

Thought I'd better ask.

Grant/NQ5T


On Jul 16, 2009, at 9:52 PM, David Y. wrote:

> Grant,
>
> I think that "equates" to an open circuit.  By the way, congrats on  
> having a meter that reads that high!
>
> Dave W7AQK
>
>
> ----- Original Message ----- From: "Grant Youngman" <[email protected]>
> To: "Elecraft Reflector" <[email protected]>
> Sent: Thursday, July 16, 2009 7:33 PM
> Subject: [Elecraft] Question on KRX3 Installation
>
>
>> In errata C-7 dated March 15, 2009, page 1, there are instructions to
>> cut two traces in the area to the right of D40 on the RF board.
>>
>> The instructions indicate that these cuts should read open  
>> circuit.  I
>> read about 14M ohms on both -- and I have cut them cleanly.
>>
>> Is this right?  Am I missing something?
>>
>> Thanks ... Grant/NQ5T
>> ______________________________________________________________
>> Elecraft mailing list
>> Home: http://mailman.qth.net/mailman/listinfo/elecraft
>> Help: http://mailman.qth.net/mmfaq.htm
>> Post: mailto:[email protected]
>>
>> This list hosted by: http://www.qsl.net
>> Please help support this email list: http://www.qsl.net/donate.html
>

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to