That may be the case. But the instructions are very specific about "open circuit as if the test meter leads were not connected to anything". Even 14 megohms doesn't meet that definition.
Thought I'd better ask. Grant/NQ5T On Jul 16, 2009, at 9:52 PM, David Y. wrote: > Grant, > > I think that "equates" to an open circuit. By the way, congrats on > having a meter that reads that high! > > Dave W7AQK > > > ----- Original Message ----- From: "Grant Youngman" <[email protected]> > To: "Elecraft Reflector" <[email protected]> > Sent: Thursday, July 16, 2009 7:33 PM > Subject: [Elecraft] Question on KRX3 Installation > > >> In errata C-7 dated March 15, 2009, page 1, there are instructions to >> cut two traces in the area to the right of D40 on the RF board. >> >> The instructions indicate that these cuts should read open >> circuit. I >> read about 14M ohms on both -- and I have cut them cleanly. >> >> Is this right? Am I missing something? >> >> Thanks ... Grant/NQ5T >> ______________________________________________________________ >> Elecraft mailing list >> Home: http://mailman.qth.net/mailman/listinfo/elecraft >> Help: http://mailman.qth.net/mmfaq.htm >> Post: mailto:[email protected] >> >> This list hosted by: http://www.qsl.net >> Please help support this email list: http://www.qsl.net/donate.html > ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html