I don't think most of us need this function. Mine K3 S meter is good enough. See the following table for my K3: uV S meter dBm(from) S meter dBm(to) 50 S9 -77 S9 -72 25 S8 -71 S9+5 -67 12 S7 -66 S9+10 -63 6 S6 -62 S9+15 -58 3 S5 -57 S9+20 -55 2 S4 -54 S9+25 -53 1 S3 -52 S9+30 -48 0.9 S3 -47 S9+35 -42 0.8 S3 -44 S9+40 -41 0.7 S3 -40 S9+45 -37 0.6 S2 -36 S9+50 -34 0.5 S2 -33 S9+55 0.4 S2 -32 S9+60 0.3 S1
0.2 S1 0.15 S1 0.1 S0 73 DE BA4RF/David On Thu, Aug 13, 2009 at 8:07 PM, David Pratt <[email protected]>wrote: > I have just completed a full recalibration of Power and the new S-meter > calibration with successful results. I am most impressive. > > One query though... Using the SG1 to generate a 1uV and 50uV signal > source on 7040kHz, after calibration I find that the S-meter reads > S9+5db with 50uV and S4 with 1uV. This is with both the main RX and the > Sub RX. Is that what others find? > > Also, Dick, would it be possible in a future utility release, to go > straight to the Sub-RX calibration without having to do the Main RX > first? > > Many thanks for an excellent program. > > 73 > -- > David G4DMP > Leeds, England, UK > ------ > > > ______________________________________________________________ > Elecraft mailing list > Home: http://mailman.qth.net/mailman/listinfo/elecraft > Help: http://mailman.qth.net/mmfaq.htm > Post: mailto:[email protected] > > This list hosted by: http://www.qsl.net > Please help support this email list: http://www.qsl.net/donate.html > ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html