Mike Kasrich wrote:
> 
> TxG error is appearing only on 40m.  xmit ok on all bands swr is fine.  
> but showing error on 40.
> 

Check for a bad solder joint around the 40m toroids on the filter board. 
You can probably scrape the insulation from top side with an X-Acto knife
and re-solder without having to remove the toroid.  I had a similar problem
on 60m with one of my units.

http://www.mail-archive.com/[email protected]/msg75799.html

73,  Bill

-- 