When I power up my K3/100/KRX3, the secondary VFO display momentarily displays 
ERR PL1 or ERR PL2 and goes back to the VFO frequency display.  I have just 
completed the synthesizer calibration procedure, and it still displays these 
error notices.  However, if I tap DISP I get what looks like good PLL voltages 
on all bands on both PLL 1 and PLL 2.  On occasion I might see a zero reading 
on a PLL voltage.  When the radio warms up I don't see these PLL 1 and PLL 2  
error displays.    Should I reposition the KREF3 and KSYN3 boards into their 
sockets again?  Should I reposition the TMP cables again to correct this 
condition?  I did the KSYN3 mod by placing a 180K resistor in parallel with SMD 
resistor R10 on both KSYN3 boards to get a higher minimum VCO current.  I also 
wonder if this might be an ESD problem in the hamshack.  I would appreciate any 
responses.  Thanks.  Roy Morris  W4WFB