I am on pages 44 and 45 of the assembly manual and have made it through all
the steps. In going through the resistance checks, I got the following
values:

- At the power poles (12VDC), all I got was an infinite resistance no matter
which way I made the measured it.

- At the R36 test point, I got 239.5 ohms which beats the 150 ohm criteria
listed

- At the U12 test point, I got 2 different values:
   a) 4.86 kilo-ohms at the terminal furthest from the blue electrolytic
capacitor in the neighborhood of the U12 regulator
   b) 237.2 ohms at the terminal closest to the blue electrolytic capacitor
in the neighborhood of the U12 regulator

- At the U13 test point, I got the following: 423 ohms.


Question: Am I okay to go ahead and apply power for the initial power on
check (aka "smoke test") on page 46?

Please advise

73

Steve 

KC2VNI




-- 
View this message in context: 
http://n2.nabble.com/K3-Build-Questions-tp4410947p4410947.html
Sent from the Elecraft mailing list archive at Nabble.com.