I have K2/100 ser. 5621 which has bee working perfectly but suddenly began giving a "hi cur" msg. The output on the Bird 43 shows 15 when set to 7 and 75 to 150 when set anywhere between 50 and 100watts on all bands. I have measured voltages on the KPA100 and so far found that U1-21 and, of course, U2-6 read 5v rather than 0v. Also U2-13 measures .7 rather than 13.8v Diodes D12 and D14, cathode end gives a voltage which is 25 - 30 volts lower than the chart both on Tx and Rx while the cathode with setting over 10 watts, simply flashes up a 1 which I take as being unreadable on my digital meter. Does anyone have an idea where I should look from here?
VE3V! ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html