I got similar results into a "high" swr. If I try 100w into a 1.6:1 swr 6m antenna i get high current alarms and it shuts down at 92W. At 88W it is Ok and doesnt alarm. I took the cushcraft 5ele down (after 5 years) and re swr'd it to 1:1 and now I can run 100W without issue
Normally i dont run into this issue as the kpa100 is bypassed on 6m as my solidstate pa only needs 5w for 450w output Dave ww2r >> Getting ready for the contest. When I transmit on 6 at 92 watts and SWR >> of >> 1.7, the power shuts down after 30 seconds of transmitting. Re-transmitt >> and it's OK for another 30 seconds. ??? >> >> Phil >> >> Philip LaMarche >> >> LaMarche Enterprises, Inc >> [email protected] >> www.LaMarcheEnterprises.com <http://www.lamarcheenterprises.com/> >> >> 727-944-3226 >> 727-937-8834 Fax >> 727-510-5038 Cell >> >> www.w9dvm.com <http://www.w9dvm.com/> >> >> K3 #1605 >> >> CCA 98-00827 >> CRA 1701 >> W9DVM >> >> >> ______________________________________________________________ ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html