I got similar results into a "high" swr. If I try 100w into a 1.6:1 swr 6m 
antenna i get high current alarms and it shuts down at 92W. At 88W it is Ok 
and doesnt alarm. I took the cushcraft 5ele down (after 5 years) and re 
swr'd it to 1:1 and now I can run 100W without issue 

Normally i dont run into this issue as the kpa100 is bypassed on 6m as my 
solidstate pa only needs 5w for 450w output 

Dave 

ww2r 


>> Getting ready for the contest.  When I transmit on 6 at 92 watts and SWR 
>> of
>> 1.7, the power shuts down after 30 seconds of transmitting.  Re-transmitt
>> and it's OK for another 30 seconds. ??? 
>>
>> Phil 
>>
>> Philip LaMarche 
>>
>> LaMarche Enterprises, Inc
>> [email protected]
>> www.LaMarcheEnterprises.com <http://www.lamarcheenterprises.com/> 
>>
>> 727-944-3226
>> 727-937-8834 Fax
>> 727-510-5038 Cell 
>>
>> www.w9dvm.com <http://www.w9dvm.com/> 
>>
>> K3 #1605 
>>
>> CCA 98-00827
>> CRA 1701
>> W9DVM 
>>
>>
>> ______________________________________________________________
 

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to