Hello Dear Electric's developers,

I found an issue in Technology Wizard.
For DRC rule OD.C.4 our technology (NWell P active overhang (J)) in section Nwell/Implant
procedure of creating XML Tech. File works incorrect. The matter is that
Nwell layer is built in node section badly (incorrect size).

You can fix tool/user/techEditWizard/techEditWizardData.java file where
in 3734 line should be state after character = nwell_overhang_diff_p.value instead
nwell_overhang_diff_n.value

Fix this issue please ASAP. It generate incorrect nodes.

--
Yours sincerely,
  Artem

--
You received this message because you are subscribed to the Google Groups "Electric 
VLSI Editor" group.
To post to this group, send email to [email protected].
To unsubscribe from this group, send email to 
[email protected].
For more options, visit this group at 
http://groups.google.com/group/electricvlsi?hl=en.

Reply via email to