Hello, Allen Li <vianchielfa...@gmail.com> writes:
> On Thu, Dec 21, 2017 at 5:55 PM, Ihor Radchenko > <ihor_radche...@mymail.sutd.edu.sg> wrote: >> >> org-clock-in in org-clock.el calculates org-clock-total-time via calling >> (org-clock-sum-current-item (org-clock-get-sum-start)). >> However, org-clock-get-sum-start returns the time in UTC, which is not >> considered by org-clock-sum-current-time. >> >> My time zone if UTC+8 and org-clock-mode-line-total is 'today. Hence >> org-clock-total-time is gives total time starting from 8am today (which >> is midnight in UTC) instead of midnight in UTC+8. > > This sounds like a continuation of Org mode’s timezone issues. Indeed. This is a leftover from timezone issues. I removed it. Thank you. Regards, -- Nicolas Goaziou