Bugs item #2924185, was opened at 2009-12-31 14:20 Message generated for change (Tracker Item Submitted) made by nobody You can respond by visiting: https://sourceforge.net/tracker/?func=detail&atid=106744&aid=2924185&group_id=6744
Please note that this message will contain a full copy of the comment thread, including the initial issue submission, for this request, not just the latest update. Category: None Group: None Status: Open Resolution: None Priority: 5 Private: No Submitted By: Nobody/Anonymous (nobody) Assigned to: Nobody/Anonymous (nobody) Summary: wrong BASE_PERIOD in "test axis" dialog Initial Comment: If step lenght > 5.000, I found a wrong timing of the base_thread. e.g. step len = 20.000, jitter = 20000 results in min base_period = 40.000, max freq = 12.500 Hz displayed on the first page of Stepconf. This is correct. But when I do the "test axis" dialog and measure the pulses with a scope, the base_period is approx. 53.000. The base_period performes well, when steplen <= 5000 is used. When export ini+hal and use EMC (2.3.4), the base_period is also fine. ---------------------------------------------------------------------- You can respond by visiting: https://sourceforge.net/tracker/?func=detail&atid=106744&aid=2924185&group_id=6744 ------------------------------------------------------------------------------ This SF.Net email is sponsored by the Verizon Developer Community Take advantage of Verizon's best-in-class app development support A streamlined, 14 day to market process makes app distribution fast and easy Join now and get one step closer to millions of Verizon customers http://p.sf.net/sfu/verizon-dev2dev _______________________________________________ Emc-developers mailing list Emc-developers@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-developers