Bugs item #2924185, was opened at 2009-12-31 14:20
Message generated for change (Tracker Item Submitted) made by nobody
You can respond by visiting: 
https://sourceforge.net/tracker/?func=detail&atid=106744&aid=2924185&group_id=6744

Please note that this message will contain a full copy of the comment thread,
including the initial issue submission, for this request,
not just the latest update.
Category: None
Group: None
Status: Open
Resolution: None
Priority: 5
Private: No
Submitted By: Nobody/Anonymous (nobody)
Assigned to: Nobody/Anonymous (nobody)
Summary: wrong BASE_PERIOD in "test axis" dialog

Initial Comment:
If step lenght > 5.000, I found a wrong timing of the base_thread.
e.g. step len = 20.000, jitter = 20000 results in min base_period = 40.000, max 
freq = 12.500 Hz displayed on the first page of Stepconf.
This is correct.
But when I do the "test axis" dialog and measure the pulses with a scope, the 
base_period is approx. 53.000.
The base_period performes well, when steplen <= 5000 is used.
When export ini+hal and use EMC (2.3.4), the base_period is also fine.

----------------------------------------------------------------------

You can respond by visiting: 
https://sourceforge.net/tracker/?func=detail&atid=106744&aid=2924185&group_id=6744

------------------------------------------------------------------------------
This SF.Net email is sponsored by the Verizon Developer Community
Take advantage of Verizon's best-in-class app development support
A streamlined, 14 day to market process makes app distribution fast and easy
Join now and get one step closer to millions of Verizon customers
http://p.sf.net/sfu/verizon-dev2dev 
_______________________________________________
Emc-developers mailing list
Emc-developers@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/emc-developers

Reply via email to