On Wed, Aug 04, 2010 at 11:11:44PM -0400, Brian wrote: > I am not 100% sure what version I moved from, I will look into it. I > am sure the tooltable is updated, as it works fine on initial startup, > its only after I invoke the 'reload tool table' function that things > break. > > As for listing my config, can I put an attachement on these emails, or > is there a better way to share it? > > Brian
You can tar up your whole config directory and attach it. I think the limit on the list for attachments is 24kB. Otherwise if you don't have web space of your own, use a sharing service like filebin.ca, pastebin.ca, etc. Much better would be for you to figure out a way to reproduce the problem on a sim configuration and share that one. That was interested people (like me!) can just run it and see the problem. If step by step instructions are required, please give us those too. Here is what I did: I tested 2.4.2 (configuration sim/axis) by loading and running comp311.ngc (which uses T4, which had a diameter of 0.25 in my tool table). comp311 does the same path twice, once with and once without comp. This runs correctly and I get both paths and they match the preview. Then I changed T4 to 0.5 diameter and reloaded the tool table (at which time the status line at the bottom of the screen updated and the tool got bigger in the preview.) I then reloaded the file with control-R and got a new preview with more comp offset. Running the program gives me a path with the larger comp. So for me, it works as expected, both in the preview and the actual tool path. Chris ------------------------------------------------------------------------------ The Palm PDK Hot Apps Program offers developers who use the Plug-In Development Kit to bring their C/C++ apps to Palm for a share of $1 Million in cash or HP Products. Visit us here for more details: http://p.sf.net/sfu/dev2dev-palm _______________________________________________ Emc-developers mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-developers