Il giorno lun, 05/12/2011 alle 19.01 +0100, Michał Geszkiewicz ha scritto: > If you want to make halui.jog-speed pin working in ja3 branch, comment > line 1223 (axis->teleop_tp.max_vel = axis->vel_limit;) in file > /src/emc/motion/control.c and recompile > > regards, > Michael
YYYYYYYEEEEEEEEEEEESSSSSSSSSSSSSSSS!!!!!!!!!!!!!!! Hi and thank you Michael. It worked. (was it so simple!?) Just for knowledge, what's the reason of that line? ------------------------------------------------------------------------------ All the data continuously generated in your IT infrastructure contains a definitive record of customers, application performance, security threats, fraudulent activity, and more. Splunk takes this data and makes sense of it. IT sense. And common sense. http://p.sf.net/sfu/splunk-novd2d _______________________________________________ Emc-developers mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-developers